Convection

attika
RAIS/
stoves are convection stoves. Therefore the external stove panels is a lot
cooler than the inner body. Convection means that the air is circulated in the room so
that heat is evenly distributed.
The
air is drawn in at the base of the stove, and up through the convection chan-
cold
nel and flows along the stove's combustion chamber.
The
heated
air flows out of the oven top, and ensures warm air circulation in the
room.
Please note that you must use extreme care as all exterior surfaces become hot during
the stove's use.
The stove is equipped with "cold" door handle - a specialty from RAIS - which means
that you able to operate your stove almost without gloves. Please note, that all outer
surfaces become hot during the stove's use - you need to take extreme care.

Chimney

The chimney is the driving force to get the wood burning stove to function. Remember
that even
the best stoves do not burn optimally without the necessary and proper draught in the
chimney.
The chimney must be high enough - a minimum of 3 metres and updraught apertures
allowing between -12 to -25 pascal. If the chimney draught is lower than recommend-
ed, there may be problems of smoke leaking into the room when the stove is lit.
Note that there are often national and local regulations concerning houses with
thatched roofs.
Please also note the draught conditions in the chimney with 2 cores.
The stove is suitable for connection with the flue, but we recommend that fuel is
placed so there is a minimum of 250 mm ground clearance difference between these.
The flue pipe is 150 mm in diameter.
If the draught is too strong, it is recommended to provide the chimney or flue pipe with
a damper. In which case, it is important to ensure that there is a free flow -through area
of minimum 20 cm² when the regulating damper is shut. Otherwise, the fuel energy
may not be used optimally. If you are in doubt about the condition of the chimney,
contact a chimney sweep.
Remember, there must be free access to the cleaning latch.
Make sure that there is access for cleaning the fireplace, flue collar and flue.