Herunterladen Inhalt Inhalt Diese Seite drucken

ABB Orion1 Base Bedienungsanleitung Seite 9

Vorschau ausblenden Andere Handbücher für Orion1 Base:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
Receiver
Function
Status
Alignment
TEST
(red on)
Reception
(green on)
Beams interrupted
(red on)
Normal
Interlock
operation
Beams free
mode
(red on
yellow on)
Interlock
Beams interrupted
(red on
yellow on)
Alignment level
EDM enabled
Function
Type
OSSD error
(red on)
Internal error
(red on)
Optical error
(red on)
Error mode
EDM error
(red on)
Reset selection error
(red on)
No power supply
(LEDs off)
2TLC172293M0201 Rev A
2015-03-20
Meaning
See paragraph "Alignment procedure" of the instruction
manual.
AOPD being tested.
OSSD outputs off.
AOPD working in normal operating mode.
OSSD outputs on.
Beam(s) interrupted in Automatic Reset.
OSSD outputs off.
AOPD in interlock, waiting for reset.
OSSD outputs off.
Beam(s) interrupted in Manual Reset.
AOPD in interlock.
OSSD outputs off.
Minimum
(1 bar)
Medium
(2 bars)
Maximum
(3 bars)
EDM function is selected.
Check and repair
Check the wiring and connections of the OSSD outputs. Make
sure that there is no short-circuit between them or with the
supply voltage. See also "Connection examples". Then
Acknowledge.
If the error persists, contact your ABB Jokab Safety
representative.
Switch the power off and on.
If the error persists, contact your ABB Jokab Safety
representative.
Acknowledge.
If the error persists, contact your ABB Jokab Safety
representative.
Check the wiring and connections of the EDM as well as the
time sequence (see Time chart in the instruction manual).
If the error persists, contact your ABB Jokab Safety
representative.
Check the wiring and connections of the MAN / AUTO pin (see
paragraph "Receiver (RX)" off the instruction manual).
If the error persists, contact your ABB Jokab Safety
representative.
Check the wiring and the connections of the power supply.
Check that its value is within the allowed range.
If the error persists, contact your ABB Jokab Safety
representative.
9
LED
DIGIT
LED
DIGIT
www.abb.com/jokabsafety

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis