Operating Instructions
Display
seat switch
open!
dirty tank full
cleaning stops
controller temp.
exceeded: xx°C
error!
bus communication
error!
linear actuators
error!
contactor closed
error!
traction
error!
traction
26
Cause
Seat contact switch is not activated.
Dirty water tank is full.
The controller temperature is critical.
xx = temperature display 0°C..99°C.
The communication between the
microprocessors of the controller has
broken down.
Motor current too high or interruption to
one or both linear actuators.
Main contactor already closed when the
key-operated switch is switched on
(contacts stick).
Message appears when key-operated
switch is switched on.
Checking of the motor electronics has
detected an error.
Message occurs during movement. The
traction is defective.
Remedial measures
- The unit only operates when the operator is sitting in the
seat.
Call customer service if the error still occurs.
- Empty the dirty water tank.
Call customer service if the error still occurs.
- Wait until the temperature has dropped to at least
59°C.
The current temperature can be requested by pressing the
Info button several times. Cleaning is no longer possible
above 60°C. The traction current is reduced. Above 70°C the
unit can only be driven on level ground. Optional lighting and
horn are still working.
- Call customer service.
- Check fuse F7. *
- Exchange with prescribed value.
Call customer service if the error still occurs.
- Call customer service.
- Check fuse F2. *
- Exchange with prescribed value.
Call customer service if the error still occurs.
- Call customer service.