Beep codes for fatal errors, which halt the boot process, are communicated
through a series of audible beeps. If AMIBIOS POST can initialize the
system video display, it displays the error message on the screen.
Displayed error messages, in most cases, let the system continue to boot.
Refer to
the CPV5300 CompactPCI BIOS and Programmer's Reference Guide
(part number CPV5300A/PGx) for information about the CPV5300 with
the PhoenixBIOS.
Table 3-4. AMIBIOS Beep Codes for Fatal Errors on the System
This number
With this error
of Beeps:
message:
1
Refresh Failure
2
Parity Error
3
Base 64 KB Memory
Failure
4
Timer Not Operational
5
Processor Error
6
8042 - Gate A20 Failure cannot switch to protected mode
7
Processor Exception
Interrupt Error
8
Display Memory
Read/Write Error
9
ROM Checksum Error
10
CMOS Shutdown
Register Read/Write
Error
11
Cache Memory Bad -
Do Not Enable Cache
http://www.motorola.com/computer/literature
Table 3-4
for a description of the AMIBIOS beep codes. Refer to
Tells you:
the memory refresh circuitry is faulty
about a parity error in the base memory (the first 64
KB block memory)
about memory failure in first 64 KB
about a memory failure in the first 64 KB of
memory, or Timer 1 is not functioning
the CPU generated an error
the CPU on the CPU card generated an exception
interrupt
the system video adapter is either missing or its
memory is faulty. This is not a fatal error
the ROM checksum value does not match the value
encoded in AMIBIOS
the shutdown register for CMOS RAM has failed
the cache memory test failed. Cache memory is
disabled. Do not press <Ctrl> <Alt> <Shift> <+> to
enable cache memory
Installation Troubleshooting