Herunterladen Diese Seite drucken

Husqvarna WR 250/2008 Werkstatt-Handbuch Seite 245

Werbung

ADJUSTMENT
STANDARD setting for COMPRESSION: when in "completely closed" position,
unscrew by 23 clicks.
STANDARD setting for REBOUND: when in "completely closed" position, unscrew
by 10 clicks.
FIG. 37
Damping rate during COMPRESSION can be adjusted by turning the screw
adjuster (A), at the bottom of each leg, with a flat screwdriver. To reach the
adjuster, remove the protection plug (B) first. When adjusting, ALWAYS start with
the "completely closed" position, which can be reached by turning the adjuster
completely clockwise until it locks. Then, turn the screw counter clockwise to the
required position.
Each adjustment "clicks" in position.
IMPORTANT: Do not force the adjuster beyond the maximum closing and opening
position.
FIG. 38
Damping rate during REBOUND can be adjusted by turning the screw adjuster
(19) on the top of each leg with a small flat screwdriver. In order to change the
adjustment unit position, ALWAYS start with the "completely closed" position,
which can be reached by turning clockwise the adjuster until it locks. Turn the
adjuster counter clockwise until the wished position is reached.
Each adjustment "clicks" in position.
IMPORTANT: Do not force the adjuster beyond the maximum closing and opening
position.
8000B0543 (06-07)
FRAME, SUSPENSIONS AND WHEELS
FIG. 34
FIG. 35
FIG. 36
FIG. 37
FIG. 38
I.33

Quicklinks ausblenden:

Werbung

loading

Diese Anleitung auch für:

2007 wr 250