Herunterladen Inhalt Inhalt Diese Seite drucken

Menu Structure - IKA RV 10 series Betriebsanleitung

Rotationsverdampfer
Vorschau ausblenden Andere Handbücher für RV 10 series:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4

Menu structure

Evaporator
Menu
Modes
Automatic
Manual...................................................................................................... 1013 mbar
Pump %...................................................................................................... 50%
Volume
Program..................................................................................................... -
100%
Start after...
Cleaning
Duration
Pump speed
Clean now.................................................................................................. -
Manual
Limits
Pump %
Automatic............................................................................................. 
Hysteresis
Manual
Solvent library
Add solvent
Add solvent
Add solvent
Add solvent
Add solvent
Acetic acid
Acetone
Acetonitrile
...
Xylene
Name.......................................................................................................... Acetic acid
Calculator
Vapor temperature ..................................................................................... 40 °C
Heating bath temperature............................................................................ 60 °C
Pressure...................................................................................................... 46 mbar
Stop heating........................................................................ -
Actions after distillation
Stop rotation....................................................................... 
Lift up.................................................................................. 
Close water valve................................................................. 
Open venting valve.............................................................. 
Cleaning............................................................................. -
Bath medium.............................................................. Water
Start temperature........................................................ 60 °C
Solvent....................................................................... Acetic acid
Target......................................................................... 100 ml
Efficiency..................................................................... 80%
Adjustment.................................................................. -
Solvent...................................................................... Acetic acid
Drying........................................................................ -
mm:ss....................................................................... 30:00
mm:ss....................................................................... 06:00
Value........................................................................ 20%
Minimum..................................................................... 2 mbar
Maximum..................................................................... 1013 mbar
Minimum..................................................................... 0%
Maximum.................................................................... 100%
Value............................................................................. ±15 mbar
Name.................................................................... -
Formula................................................................. -
Bath temperature................................................... -
Rotation speed...................................................... -
Boiling point.......................................................... -
Efficiency................................................................ -
Heat capacity......................................................... -
Enthalpy................................................................. -
Density................................................................... -
i-factor................................................................... -
Name.................................................................... -
Formula................................................................. -
Bath temperature.................................................. -
Rotation speed...................................................... -
Boiling point.......................................................... -
Efficiency............................................................... -
Heat capacity......................................................... -
Enthalpy................................................................ -
Density.................................................................. -
i-factor.................................................................. -
Factory settings
44

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rv 10 controlRv 10 auto

Inhaltsverzeichnis