Dimplex DHW 300VD+ Montage- Und Gebrauchsanweisung Seite 39

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DHW 300VD+
Menu block
Menu item
ventilation
service interval
service reset
level 0 active
level manual
level 1
level 2
level 3
level auto min
level auto max
HP op. Flow
silent speed
scale
modus
contrast
diagnostic
Messages
Alarms
www.gdts.one
Parameter
Value
HD input
off ... 12 ... 18 months
yes / no
on / off
0* / 1 / 2 / 3 / Auto
30 ...60 m³/h...300 m³/h
30 ...90 m³/h...300 m³/h
30 ...120 m³/h...300 m³/h
30 ...60 m³/h...60 m³/h
60 ...120 m³/h...300 m³/h
140 ...200 m³/h...300 m³/h
100 ...100 m³/h...100 m³/h
20 ... 30 ... 50
Modbus
BMS
PVO
Address
0...2...255
Baud rate
4800...19200
Parity
O...E...N
-30...-10...30
451905.66.07 · FD 9908
Description
Not used
Setting the time interval as a reminder to carry out the filter change
and maintenance
Confirmation of the maintenance and restart of the time interval
counter
If 'off' is set, no level 0 can be activated, i.e. ventilation always takes
place in levels 1 to 3.
Ventilation level if no time program is active/ basic operation
Setting the volume flow in level 1 for the exhaust air function with-
out heat pump operation
Setting the volume flow in level 2 for the exhaust air function with-
out heat pump operation
Setting the volume flow in level 3 for the exhaust air function with-
out heat pump operation
Requires the sensor accessory. Setting the minimum volume flow
to be permitted in automatic operation.
Requires the sensor accessory. Setting the maximum volume flow
to be permitted in automatic operation.
Setting the volume flow for heat pump operation
Setting the volume flow for heat pump operation during the active
time program "Silent"
Scaling factor for moving the volume flow characteristic curve in
parallel during calibration.
Diagnostic displays
Displays the alarms, frequency and type
English
EN-15