Hydro Unit
8
Frost Protection
Back Up Heater
9
Control
10
Night Setback
Hydro 2 Way
12
Valve Operation
Control
Hydro 3 Way
13
Diverting Valve
Operation Control
2 Zone Mixing
14
Valve Drive Time
Boiler/Heat Pump
15
Synchronisation
Maximum
Operation Time Of
16
Hot Water Heat
Pump
17
Cooling Operation
Remote controller
18
Indication
CDU Night Time
19
Low Noise
Operation
20
Alarm Tone
Second Remote
controller and
21
room temperature
thermostat
51-EN
FC Description
Function 0 = Invalid; 1 = Valid
Frost Protection Setting
Temperature (°C)
End days
End times
Downtime Back Up Heater
0 = 5min; 1 = 10min;2 = 15min;
3 = 20min
Uptime Back Up Heater
0 = 10min; 1 = 20min;
2 = 30min; 3 = 40min
Change Setback Temperature
Zone selection 0 = Zone 1 & 2;
1 = Zone 1 Only
Start Time (Hour)
End Time (Hour)
Cooling 2 Way Valve -
Operation Logic 0 = Activated
during cooling; 1 = Not
activated during cooling
3 Way Diverting Valve
Operation Logic 0 = Activated
during hot water operation;
1 = not activated during hot
water operation
Specified Drive Time for
Mixing Valve (x10sec)
Mixing valve OFF (control time
- mins)
External Boiler/Heat Pump
Synchronisation
0 = Synchronised; 1 = Not
synchronised
Maximum Heat Pump
Operation Time In Hot Water
Operation Priority Mode
(minutes)
0 = Cooling & Heating
Operation; 1 = Heating Only
Operation
24h or 12h Time Indication
0 = 24h; 1 = 12h
Low Noise Operation
0 = Invalid; 1 = Valid
Start Time (Hour)
End Time (Hour)
Tone Switching
0 = OFF; 1 = ON
Choice of the initial setting
temperature
0 = The fixed temperature by
FC9D
1 = The calculated
temperature by Auto curve
Fixed initial temperature
setting
Location & FC
Number
Hydro
RC
Range
3A
0~1
3B
10~20 °C
12
0~20
13
0~23
33
0~3
34
0~3
26
3~20 °C
58
0~1
0E
0~23
0F
0~23
3C
0~1
54
0~1
0C
3~24
59
1~30
3E
0~1
07
1~120
02
0~1
05
0~1
09
0~1
0A
0~23
0B
0~23
11
0~1
B5
0~1
9D
20~55 °C
– 51 –
Installation Manual
After
Change
Default
Commissioning
1
15
0
0
1
0
5
0
22
06
0
0
6
4
0
30
0
0
0
22
06
1
0
40