Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba HWS-455XWHM3-E Installationshandbuch Seite 47

Vorschau ausblenden Andere Handbücher für HWS-455XWHM3-E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Hydro Unit
 Service monitor
• The sensor sensing temperature is displayed on the
remote controller.
• This function allows you to make sure whether the
sensor is installed properly.
(1) Press the [
] / [
"Service monitor" on the FIELD SETTING MENU
screen, then press the [
FIELD SETTING MENU(2/2)
Service monitor
FC for Hydro unit
FC for Remote controller
(2) Press the [
] button to select the unit, then press
the [
] button to display the status.
Service monitor
UNIT 1
UNIT 4
UNIT 2
UNIT 5
UNIT 6
UNIT 3
UNIT
Service monitor
Code
RETURN
] button to select
] button.
SET
UNIT 7
UNIT 8
SET
Data
– 46 –
code
Data name
00
Control temperature (Hot water cylinder)
01
Control temperature (Zone1)
02
Control temperature (Zone2)
03
Remote controller sensor temperature
04
Condensed temperature (TC)
06
Water inlet temperature (TWI)
07
Water outlet temperature (TWO)
08
Water heater outlet temperature (THO)
09
Floor inlet temperature (TFI)
0A
Hot water cylinder temperature (TTW)
0B
Mixing valve position
0E
Low pressure (Ps) × 1/10
0F
Hydro soft ver.
code
Data name
60
Heat exchange temperature (TE)
61
Outside air temperature (TO)
62
Discharge temperature (TD)
63
Suction temperature (TS)
65
Heat sink temperature (THS)
6A
Current × 10
6D
Heat exchanger coil temperature (TL)
70
Compressor operation Hz
Number of revolutions of outdoor fan
72
(lower or 1 fan model)
Number of revolutions of outdoor fan
73
(upper)
74
Outdoor PMV position × 1/10
7A
Discharge pressure (PD) × 1/10
code
Data name
Micro computer energized accumulation
F0
time × 1/100
Hot water compressor ON accumulation
F1
time × 1/100
Cooling compressor ON accumulation
F2
time × 1/100
Heating compressor ON accumulation
F3
time × 1/100
Built-in AC pump operation
F4
accumulation time × 1/100
Hot water cylinder heater operation
F5
accumulation time × 1/100
Backup heater operation accumulation
F6
time × 1/100
Booster heater operation accumulation
F7
time × 1/100
• Some sensors (temperature / pressure) are not
displayed, because not connected.
Installation Manual
Unit
°C
°C
°C
°C
°C
°C
°C
°C
°C
°C
step
kPa
-
Unit
°C
°C
°C
°C
°C
A
°C
Hz
rpm
rpm
pls
kPa
Unit
h
h
h
EN
h
h
h
h
h
46-EN

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis