G
B
RADIO CODE FULL MEMORY TEST
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts
blinking slowly. If the green LED DL9 flashes six times, it means that the
F
UNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF)
ATTENTION:
ONLY
COMMANDS
HAVE
CONNECTED.
Make sure that any other type of
command accessories (e.g. mass
detectors) used on the installation are
set in the IMPULSIVE mode, otherwise,
the gate will be operated even without
the protection of the safety devices.
OPEN1 BUTTON (COM - OPEN1)
The OPEN1 button performs the open
command, regardless the position of the
boom arm. If the OPEN1 button is pressed
during the closing, the boom arm stops and
will reverse the movement in opening.
In PARK MODE (DIP6 ON), if there is
a vehicle at the entry (see scheme 4) and
the TLC contact is closed, the OPEN1
command opens the barrier. Otherwise,
if the TLC contact is open the OPEN1
command is disabled.
CLOCK FUNCTION
If you want the Clock Function must
request PARK 230V with firmware 07
NOUP.
ATTENTION: A CLOCK CONNECTED
TO PARK 230V with fw 05 or more
ACTIVATES THE OPENING MOVEMENT
OF THE BARRIER WITHOUT HAVING
THE PROTECTION OF THE SAFETY
DEVICES!
The Clock Function permits to keep the boom arm opened even if, for
example, the Automatic Closing is enabled (DIP3 ON) or somebody
commands the barrier closing. It is useful during rush hour, when
traffic is heavy and the flow is low (e.g. entrance/exit of employees,
emergencies in residential areas or car parks) and it's necessary to
keep the boom arm opened.
CLOCK FUNCTION APPLICATION
It is necessary to request a PARK 230V control panel with firmware
07 NOUP.
It can be done by connecting a switch and/or a daily/weekly timer either
in parallel to the OPEN1 button or instead of the OPEN1 button. When
the control board receives this command, the boom arm will open and
by keeping this contact closed for all the time of the boom arm opening,
the Clock Function is automatically activated.
In fact, once reached the open position, the barrier will remain opened
and all of the control board features are blocked. Only when the OPEN1
button is released, the control board functions are re-activated and the
boom arm will close immediately.
CLOSE BUTTON (COM - CLOSE)
The CLOSE button performs the close command, regardless the
position of the boom arm.
IMPULSIVE
TO
BE
K BUTTON
STOP
CLOSE
+
OPEN 1
LSC
LSO
LSSC
LSSO
TIMER
radio code memory is FULL (maximum codes to be stored 60).
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
AERIAL
+
+
COAX
BUZZER
LED
R=2K2
-
_
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
STEP BY STEP or AUTOMATIC COMMANDS (COM - K BUTT)
DIP5 - OFF => The K BUTT performs the cyclic command open-stop-
close-stop-open etc.
DIP5 - ON => The K BUTT performs:
- the open command, if pressed with the barrier
completely closed
- the close command, if pressed with
completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is
closing
REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs the cyclic command
open-stop-close-stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with the barrier
completely closed
- the close command, if pressed with
completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is
closing
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open position can be enabled
turning ON the DIP3. The maximum time that can be programmed is 5
minutes (see Point D).
30
30
ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D
+
D
MAGNETIC LOOP
TO EXIT
the barrier