Herunterladen Inhalt Inhalt Diese Seite drucken

hager RTD111X Anleitung Seite 12

Ip netzwerk-relais
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

RTD111X
Relay configuration
Basic relay settings
IP-Adress
IP address of the IP door speaker module that should carry out
switching functions on the network relay. Up to 10 door stations
can be defined.
SIP registered
The contact is continuously connected once the IP door speak-
er module is operating and successfully registered with a SIP
server. If the contact fails, this allows the malfunction of a door
speaker module to be indicated (e.g. for safety-critical areas
such as lifts).
Incoming call
The contact us switched when a call comes into the IP door
speaker (on a call from the indoor client to the outside station).
(e.g. to implement a light switch circuit)
Establish call
The contact is switched when a call is established (ringing) on
the IP door speaker. (e.g. to operate a separate gong or bell,
send a status message to a house automation system or to im-
plement entry lighting).
Connected
The contact is switched for the duration of a call (e.g. for a dis-
play unit that signals the call state).
Combining Establish call and Connected
The switching functions "Establish call" and "Connected" can
also be combined on a single contact. This allows this contact
to remain switched from the ring to the end of the call (e.g. to
provide entry lighting).
12
Relay 1 and relay 2 (via DTMF code)
Contacts set up here are switched in a function defined in the
IP door speaker for relay 1/2 to "DTMF controlled" with the de-
fined power-on duration. The switching of the relay here takes
place when the DTMF sequence is sent from the indoor client to
the door speaker module.
Subject to technical changes
The Relay area permits configu-
ration of all the settings for swit-
ching functions.
!
A Relay share determines the
switching processes that will be
triggered by a particular IP door
speaker. A share can be created,
edited or deleted in this menu.
To accept changes, always press
the Save button at the top right.