Factory settings / reset

Factory settings

SUBNET
Subnet access to RTD111X
IP address in subnet
Access data administration
Username:
admin
Password:
1234
192.168.42.61
Reset to factory settings
# 1
+
OK OK
NETWORK
INPUT
# 2
1. Disconnect the network re-
lay from the power supply.
2. Disconnect the network
cable as well.
10
RTD110X
192.168.42.61
+
− OK OK
# 4
# 3
3. Lift the front plate carefully
out with a small screw-
driver.
4. Switch the yellow mini
switch downwards (towards
the bottom of the housing).
Subject to technical changes
MAINNET
Main network access to RTD111X
IP address in main network RTD110X-IP:Port
Access data administration
Username:
admin
Password:
1234
RTD110X-IP:Port
# 5
+
− OK OK
# 6
5. Connect the IP network
relay to the power supply
again.
6. Wait a moment until all the
contact LEDs have lit up.
A reset is then carried out.
+
OK OK
# 7
# 8
7. Switch the yellow mini
switch back up.
8. Close the housing. After
connecting to the network,
the device is reachable at
the factory-configured IP
address.
www.hager.com