Herunterladen Inhalt Inhalt Diese Seite drucken

Guard Limits; Alarms Screen - voestalpine Böhler Welding URANOS 2700 MTE Betriebsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63

3.12 Guard limits

Allows the welding process to be controlled by setting warning
limits
and guard limits
main measurable parameters :
Welding current
Welding voltage
Enter set-up by pressing the encoder button for at least 5 sec-
onds.
Select the required parameter (801).
Enter the "Guard limits" screen by pressing the encoder button.
Select the required parameter by pressing button (1)
Select the method of setting the guard limits by pressing button
(2)
.
Absolute value
%
Percentage value
7 Warning limits line
8 Alarm limits line
9 Minimum levels column
10 Maximum levels column
Select the required box by pressing the encoder key (the select-
ed box is displayed with reverse contrast).
Adjust the level of the selected limit by rotating the encoder.
Save and exit the current screen by pressing button (4)
for the
Passing one of the warning limits causes a visual signal to appear
on the control panel.
Passing one of the alarm limits causes a visual signal to appear
on the control panel and the immediate blockage of the weld-
ing operations.
It is possible to set start and end of welding filters to prevent
error signals during the striking and extinction of the arc (consult
the "Set up" section - Parameters 802-803-804).

3.13 Alarms screen

Allows the intervention of an alarm to be indicated and provides
the most important indications for the solution of any problem
encountered.
.
1
Alarm icon
2
Alarm code
3
Alarm type
Alarm codes
E01, E02 Temperature alarm
It is advisable not to switch off the equipment while the alarm
is on; the internal fan will thus keep operating and will help to
cool the overheated parts.
E07
Wire feed motor supply alarm
E08
Blocked motor alarm
E10
Power module alarm
.
E13
Communication alarm
51

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis