To replace the air filters
1. Open the 3 clamps of the air filter housing and
remove the air filter housing.
2. Replace the outer air filter and the inner air filter.
3. Install the air filters in opposite sequence.
Note: If the 3 clamps of the air filter housing cannot
be closed, the outer air filter is not correctly installed.

Battery maintenance

Note: The battery on your product is maintenance free.
Do not open or remove the caps or the covers.
To connect and disconnect the battery
1. Connect the red battery cable (A) to the POSITIVE
(+) battery terminal on the battery.
-
C
2. Install the battery holder (B).
3. Connect the black battery cable (C) to the
NEGATIVE (-) battery terminal on the battery.
4. Disconnect the battery cables in the opposite
sequence of how they were connected.
1143 - 002 - 08.07.2019
B
A
To do a check of the battery
Do a check of the battery daily.
a) Set the engine start switch to the ignition on
position.
b) Examine the battery gauge in the display. It must
not be below 12V.
If the battery gauge is below 12V, charge or replace
the battery.
Replace the battery if it cannot keep the voltage.
This can occur if the product is not operated for a
long time. For information about recommended
batteries, refer to
Charge the battery regularly.
Keep the battery terminals and the battery cables
clean.
To do an emergency start of the engine
If the battery is too weak to start the engine, you can use
jumper cables to do an emergency start. This product
has a 12 V system with negative ground. The product
that is used for the emergency start must also have a 12
V system with negative ground and minimum 700 CCA.
To connect the jumper cables
WARNING: Risk of explosion because of
+
explosive gas that comes from the battery.
Do not connect the negative terminal of the
charged battery to or near the negative
terminal of the weak battery.
CAUTION: Do not use the battery of your
product to start other vehicles.
WARNING: Always disconnect the
NEGATIVE (-) battery terminal first.
0
12
10
14
8
18
V
CURRENT:
4.00˝
Technical data on page 41 .
4
150
5.0
WORKING HOURS
110
STOP:
1.50˝
35