Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Assembly
Important! The fitting must be installed,
flushed and tested after the valid norms.
The hot and cold supplies must be of equal
pressures.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temperature: 65° C
Centre distance:
Connections G ½:
Rate of flow by 0,3 MPa:
Back flow and vacuum breaker
Hansgrohe mixers can be used together with hy-
draulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15
MPa.
Important!
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).

Operation

Hot surface!
English
max. 1 MPa
1,6 MPa
max. 80° C
170 mm
cold right
hot left
approx. 20 l/min
Spare parts (see page 3)
1
handle
2
screw cover for cold / hot water 97987000
3
sleeve
4
aerator cpl. M24x1
5
shut off unit,
6
non return valve
7
selector
8
noise reduction
9
pillar union
10
sliding gear lever
11
cover cap set
12
shower base
13
shower holder
14
hose 1,25 m
15
filter packing
XXX = Colors
000 chrome plated
820 brushed nickel
830 polished nickel
16597XXX
97993XXX
98575XXX
94009000
94074000
98591000
96429000
98622XXX
98594XXX
98593XXX
98590XXX
16320XXX
28112XXX
94246000
7

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Axor montreux16547 serie

Inhaltsverzeichnis