Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting The In40-D03; In40-D0202K Safety Switches - Sick In4000 Standard In40-D0101K Operating Instructions

Sicherheitsschalter
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating Instructions
IN4000 Standard
WARNING
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice • 8010934/YTC9/2016-04-01
Mounting
4.2
Mounting the IN40-D03.. and

IN40-D0202K safety switches

The IN40-D0303K and IN40-D0202K safety switches
are not allowed to be mounted flush.
• The IN40-D0303K safety switch is not allowed to be
mounted flush; this type of mounting results in the
categorisation I2A18SP2M as per EN 60 947-5-2.
• The IN40-D0202K safety switch is not allowed to be
mounted flush; this type of mounting results in the
categorisation I2A30SP2M as per EN 60 947-5-2.
• Flush installation is allowable using IN40-D0304K
safety switch: this type of mounting results in the
classification I2A18SP2M as per EN 60 947-5-2.
• Pay attention to safe switch off distance and enable
zone (cf. Tab. 2, Tab. 3 and Tab. 4).
• The minimum distances stated in Fig. 6, Fig. 7 and
Fig. 8 for neighbouring sensors, sensors mounted
opposite and the minimum distances to fixed parts
of the plant and walls must be observed.
Chapter 4
77

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Inhaltsverzeichnis