Herunterladen Inhalt Inhalt Diese Seite drucken

Important Operating Notes - Truma BG 10 Gebrauchsanweisung

Boiler gas / boiler gas/elektro
Vorschau ausblenden Andere Handbücher für BG 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
The gas system must be checked every two
years by a qualified technician and confirmed
on an inspection certificate.
The vehicle owner is responsible for having
the check carried out.
Liquid gas equipment must not be used when
refuelling, in multi-storey car parks, in garages
or on ferries.
A little smoke or smell may be generated for
a short time when starting up a new device
for the first time (or if the device has not been
used for a long time). It is then advisable to
set the device to burn at maximum power and
ensure that the room is well ventilated.
Any unusual burner noise or flame blow-off
suggests a fault in the gas pressure regulation
system, and makes it necessary to check the
gas pressure regulation system.
Heat-sensitive objects such as spray cans
must not be stored in the compartment where
the boiler is installed, because under certain
conditions this area may be subject to elevat-
ed temperatures.
Only gas pressure regulating systems that
comply with EN 16129 (in vehicles) with a
fixed output pressure of 30 mbar may be
used for the gas systems. The flow rate of the
gas pressure regulation system must at least
match the maximum consumption of all the
devices installed by the system manufacturer.

Important operating notes

If the cowl has been placed near or directly
beneath an opening window, the device must
be equipped with an automatic shut-off device
in order to prevent operation with the window
open.
Always fit the cowl cover when the boiler is
not in use. Failure to do so may cause the de-
vice to malfunction as a result of water, dirt or
insects.
Figure 1
Before commencing a journey, fit the
cowl cover with the boiler switched off.
Please ensure that it is secure and has locked
into place (risk of accident). Defective cowl
covers must not be used.
No claims may be made under the warranty if
this instruction is not followed. It is essential
to remove the cowl cover before starting up
the boiler.
Even if the cold water system is being oper-
ated without the boiler, the boiler will still fill
with water. To avoid frost damage, the water
in the boiler must be drained by operating the
drain valve, even if the boiler has not been
used. Alternatively, two hot water-resistant
shut-off valves can be fitted upstream of the
cold and hot water connection.
Drain the boiler if there is a risk of frost.
No claims may be made under the war-
ranty if this instruction is not followed.
If connected to a central water supply (rural or
urban connection), or if more powerful pumps
are being used, a pressure reducer must be
used which will prevent pressures higher than
2.8 bar from occurring in the boiler.
9

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bge 10

Inhaltsverzeichnis