Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Fuses; Disposal; Technical Data - Truma BG 10 Gebrauchsanweisung

Boiler gas / boiler gas/elektro
Vorschau ausblenden Andere Handbücher für BG 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
The water temperature cannot be preselected, automatic
temperature limit at approx. 70 °C. The device can be
operated with gas and electricity simultaneously in order to
speed up the heating of the boiler contents.
The electric heating element is fitted with an overtem-
perature sensor. In the event of a fault, switch off at the
control panel. Check the water content, topping up if necessary
(close drain valve). Wait for 10 minutes, then switch on again.

Maintenance

We recommend the use of suitable commercially available
products to clean, sterilise and maintain the boiler. Products
containing chlorine are not suitable.
The boiler should be heated to 70 °C at regular intervals to
prevent infestation by microorganisms.
Clean the device and the ventilation slots with a dry, lint-free
cloth.

Fuses

The 12 V fuse for the boiler is on the electronic control unit on
the device.
Figure 5
The fine fuse on the electronic control unit must always be
replaced with a fuse of the same type: 1.6 A (slow-acting),
EN 60127-2-3.

Disposal

The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-Life Vehicle Regulation) must be observed.

Technical data

Determined in accordance with EN 15033 or Truma test
conditions
Manufacturer
Truma Gerätetechnik GmbH & Co. KG
Postfach 1252
85637 Putzbrunn (Munich)
Germany
Protection type
IP20
Water capacity
10 litres
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Type of gas
Liquid gas (propane/butane)
Operating pressure
30 mbar
Nominal heat load
Q
= 1.5 kW (H
); 120 g/h; C
n
i
Heating time from approx. 15 °C to approx. 70 °C
Gas mode:
Electrical mode:
Gas and electrical mode:
Voltage supply
12 V
230 V
/ 50 Hz
Power consumption at 12 V
Ignition:
0.16 A
Heating:
0.12 A
Standby:
0.05 A
Power consumption at 230 V (BGE 10)
Heating: (3.7 A) 850 W / (5.7 A) 1300 W
Standby – gas consumption
approx. 70 W
Weight without water
(BG 10)
6.9 kg
(BGE 10)
7.4 kg
Destination countries
BE, BG, RO, DK, DE, EE, FI, FR, GB, GR, HR, IS, IE, IT, LV, LT,
LU, MT, NL, NO, AT, PL, PT, SE, CH, SK, SI, ES, CZ, HU, CY
1,6 A
E1 10R-05 2604
Subject to technical changes.
Dimensions
129
Figure 6 – All dimensions in mm.
; I
11
3B/P
approx. 31 min.
approx. 29 min. (BGE 10)
approx. 16 min. (BGE 10)
30
109
Gas connector
383
347
Water
connections
Electronics
Cowl
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bge 10