Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions; Touch Panel (Tp); Power Module (Pm) - Truma Vicon 2 Einbauanweisung

Power module / touch panel
Vorschau ausblenden Andere Handbücher für Vicon 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation instructions

Installation in vehicles must accord with the technical and
administrative provisions of the individual country of use (e.g.
EN 1648, VDE 0100-721). The national legislation and regula-
tions must be observed.
In other countries always observe the respectively valid
regulations.

Touch Panel (TP)

Max. 1 Touch Panel can be connected per installed
Vicon 2 bus system using a Y-adapter (Y).
Install the Touch Panel in a place protected against moisture
and wetness.
Produce an installation opening for the Touch-Display.
max. 3
148
All dimensions in mm.
Plug in the cable from the Y-adapter (e.g. at plug X 1).
It is compulsory that the open plug X 2 is closed off with a
terminating resistor R = 120 Ω (part no. C30000-00300).
A cable outlet is possible to the side or top.
Insert the cable for strain relief into the cable guide.
X 2
X 1
Push the cable through the installation opening and lay to
the Y-adapter.
Fix the Touch Panel with 4 screws (max. 3 mm outer diam-
eter, max. torque 1 Nm).
Press the frame onto the Touch Panel until it clicks in place.
8
125
X 2
X 1
≤ 1 Nm

Power Module (PM)

Install the Power Module in a place (wall or floor) protected
against moisture and wetness.
The Power Module must be installed in a freely accessible
position without disturbing any cover elements etc.
In order to allow easier servicing, Truma recommends
installing a freely accessible diagnosis plug (part no.
C30000-00400) in the system instead of a terminating
resistor.
Installation dimensions
170
170
All dimensions in mm.
Removing the housing cover
1
Minimum installation space
To detach the housing cover, a suitably sized access opening
must be available inside. Maintain a minimum clearance of
15 mm to the housing cover if the access is closed.
Fix the device with 2 screws (no countersunk screws, max.
torque 1 Nm). ´
≤ 1 Nm
154.5
Ø 4,5
310
All dimensions in mm.
36.3
1
2
3
70
52

Werbung