7.2 Fehleranzeige:

Incident display

PRE-ALARM layer thickness
No rest phase detected
ALARM layer thickness
ALARM temperature
Battery fault
Mains failure
7. Errors and Malfunction
Fault
Flashing (alarm)
Flashing (alarm)
Acoustic signal and flashing
Acoustic signal and flashing
Acoustic signal and flashing
Acoustic signal and flashing
Acoustic signal and flashing ;
Power LED is flashing
Cause
Depth of grease layer for
Pre-alarm level
has been reached (see 3.3)
Measurement takes place
during operating phases
(inaccuracies possible)
Maximum grease layer
thickness has been reached
Inlet temperature too high
(heed standard requirements inlet water
when setting the level)
Battery contact error
Battery defective or service
life exceeded
- The system is currentless
- The display is defective
58
Remedy
Heed depth of grease height
and inform the disposer
if appropriate
Check measuring range in the
Parameters menu item and set
again if necessary
Inform the disposer
Reduce temperature of
Check battery polarity and seat
Replace the battery
- Check pre-fuse and / or RCD
- Call Customer Services