Herunterladen Inhalt Inhalt Diese Seite drucken

McQuay J-Serie Montageanleitung Seite 14

Wall mounted split type air conditioner
Vorschau ausblenden Andere Handbücher für J-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
LED Indicator Lights : Normal Operation And Fault Conditions For Cooling / Heat Pump Unit
COOL/HEAT
(GREEN/RED)
Green
Red
Red
Green
1 time
3 times
2 times
Red
4 times
5 times
ON
Note: The unit will not detect sensor missing when the compressor is ON.
Blink N times
1
ON
OFF
500ms 500ms
Blink continuously
ON
OFF
500ms 500ms
Normal Operation / Fault Indication
Cool mode
Heat mode
Auto mode in Heating operation
Auto mode in Cooling operation
Timer on
Sleep mode on
Fan mode on
Dry mode on
Room air sensor contact
Loose / Short
Outdoor coil sensor open
Indoor coil sensor open
Compressor overload /
Indoor coil sensor short /
1 time
outdoor coil sensor short
Defrost operation
Gas leak
3 times
Hardware error (tact switch pin short)
6 times
No feedback from indoor fan
EEPROM error
2
N
ON or OFF
1
3 seconds
1-12
Action
Error Code
Call your dealer
Blink E1
Call your dealer
Blink E3
Call your dealer
Blink E2
Call your dealer
Blink E4
Call your dealer
Blink E5
Call your dealer
Blink E8
Call your dealer
Blink E9
Call your dealer
Blink EE
Blinking
2
N

Werbung

Inhaltsverzeichnis