Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Sunred FT17G Anleitung

Flame torch
Vorschau ausblenden Andere Handbücher für FT17G:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting

PROBLEMS
Pilot will not light
Pilot will not stay on
Burner will not light
Any repairs to the patio heater must be carried out by a qualified person
PROBABLE CAUSES
Gas valve may be OFF
Tank fuel empty
Opening blocked
Air in supply system
Loose connection
Debris around pilot
Loose connection
Thermocouple bad
Gas leak in line
Lack of fuel pressure
Gas pressure is low
Orifice blocked
Control not on
Thermocouple bad
Pilot light assembly bent or
not in correct location
- 15 -
SOLUTIONS
Turn the gas valve ON
Refill LPG tank
Clean or replace opening
Purge air from lines
Check all fittings
Clean dirty area
Tighten connection
Replace Thermocouple
Check connections
LPG cylinder is near empty
LPG cylinder is near empty
Remove, clean and replace
Turn valve to ON
Replace Thermocouple
Place pilot light in correct position and
retry

Werbung