MuLTI PLE BuR I AL S

The optimized multiple burial search is based on a separation of signals via the digital
signal processor (DSp).
(1)
If there are multiple burials, this is clearly indicated by the number of matchstick men.
(2)
By default, the PIEPS DSP PRO/DSP SPORT will automatically search for the strongest signal.
(3)
Once the position of the first burial has been located (see fine search), press the button
MARK without moving away from this point. This signal is now suppressed. Once a signal
has been successfully suppressed, an outline appears around the matchstick man.
(4)
The PIEPS DSP PRO/DSP SPORT will automatically search for the next strongest signal.
(5)
Now continue the search as described above, and repeat the procedures until all
transmitters are located. If there are no further signals within the receiving range the
display indicates "No Signal".
Marking is possible within a range
of 5 m to the transmitting beacon.
Marking of a second transmitter is
possible after 3 seconds after marking
the first transmitter at the earliest. If
these requirements are not provided,
an alert signal sounds by pressing the
button „MARK" again.
Number of
possible marks:
max. 5 transmitters,
3 are indicated on
the display
32
|
06/15
Mu LT IPLE Bu RIAL S
Mark reset of single suppressed signals:
To reset the MARK function for single signals, press
the button MARK for 3 seconds.
Mark reset of all suppressed signals:
To reset the MARK function switch your PIEPS DSP
PRO/DSP SPORT into SEND-mode and then back to SEARCH-mode. With the PIEPS DSP PRO
you also have the possibility to reset MARK with the following described SCAN-function. All
information from previously suppressed signals is now reset and you can start with MARK again.
old device mode:
Older analog transceivers are transmitting a weak continuous signal
additional to the digital pulse signal that can have an impact on the digital signal separation. In
such cases, you may find for a short time that more signals are indicated than actually exist – the
display "number of burials" starts flashing (display of "old device mode"). To suppress (MARK)
these transmitters keep a distance of more than 1 m.
signal without continuous carrier
IMPORTAnT!
The MARK function is subject to physical and technical limitations. This applies to all
transceivers with MARK function! In practice, one might observe performance-reducing limitations which
get intensified by overlapping signals. More information can be found on www.pieps.com.
PIEPS provides with the pIEpS SafETY SYSTEM (digital PIEPS beacon and electronic probe
PIEPS iPROBE) a technical 100% solution for multiple burials. By using a digital PIEPS
beacon in combination with the PIEPS iPROBE or iPROBE ONE someone can solve a multiple
burial without any performance-reducing limitations! See also chapter „iPROBE Support".
signal with continuous carrier