Ch. 7 Maintenance and troubleshooting
DANGER
Electric shock
risk
In ordinary conditions, FLOTEC AUTOJET series electropumps do not require any maintenance. To prevent possible
problems, it is advisable to periodically check the pressure supplied and current absorption. A reduction of the pressure
may indicate that the electropump is worn. Sand and other corrosive materials present in the delivery fluid cause a
rapid wear and a reduction of performance. In this case, it is advisable to use a filter. An increase in current absorption
indicates the presence of abnormal mechanical friction in the pump and/or the motor.
If the electropump is not going to be used for a long period of time (i.e. one year), it is advisable to empty it completely (by
opening the drain cap, see Fig. 1 n. 10), rinse it with clean water and store it in a dry location, where it can be protected
from frost.
PROBLEM
1) THE PUMP IS NOT
RUNNING
2) THE PUMP DOES NOT
STOP
3) THE ELECTROPUMP
DOES NOT PUMP WATER,
THE MOTOR DOES NOT RUN
4) THE MOTOR RUNS BUT
THE ELECTROPUMP DOES
NOT PUMP LIQUID
5) THE ELECTROPUMP
STOPS AFTER RUNNING
FOR A SHORT PERIOD OF
TIME BECAUSE ONE OF THE
THERMAL MOTOR CIRCUIT
BREAKER TRIPS
If the problem persists despite the recommended corrective actions, contact the Customer Assistance Service.
10
Make sure the machine is disconnected from electric power supply,
before performing maintenance operation.
POSSIBLE CAUSE
1) No water.
2) Pump stalled.
3) No current.
4) PRESSUREMATE is faulty.
1) Reset button blocked.
2) The pump sucks air.
3) PRESSUREMATE faulty.
1) No power.
2) Motor protection tripped.
3) Defective condenser.
4) Shaft blocked.
1) The pump is sucking air.
1) The power supply does not comply
with the data on the nameplate.
2) A solid object is blocking the
impellers.
1) Red LED light on (FAILURE). Identify the
cause, and then restart by pressing the
RESTART button.
2) Identify the cause and unblock the pump.
3) Check that power is present and that the
plug has been inserted properly. The Green
LED light (power On) is off.
4) Contact the Customer Assistance Service.
1) Inspect the pump and clean it if necessary.
2) See point 4.
3) Contact the Customer Assistance Service.
1) Check that power is present and that the
plug has been inserted properly. The Green
LED light (power On) is off.
2) Identify the cause, and then restart by
pressing the RESTART button. Wait until the
system
thermoregulator has intervened.
3) Contact the Customer Assistance Service.
4) Identify what caused the block:
a) make sure that the power supply
cable has been unplugged
b) remove the fan cover
c) Try to unblock the shaft by turning the
cooling fan.
Contact customer services if the problem
persits
1) Check to ensure that joints are leak proof.
- check that liquid levels have not decreased
beneath the foot valve.
- Check to ensure that the foot valve is
unblocked and leak proof.
1) Check the voltage on the power supply
cable leads.
2) Contact customer services.