The MiniSipper is an optional accessory that enables samples to be drawn into a
flowcell of the user's choice for automatic measurement. After the measurement
is complete the sample is sent to Waste. A continuous pumping mode allows the
system to be washed through when required, e.g. between applications.
This section describes the operation of the MiniSipper with the Local Control
software. Full details of the installation and operation of the accessory are
described in the MiniSipper Installation and Maintenance Manual (9499 230
45111) supplied with the MiniSipper.
To operate the MiniSipper install as described in the above manual. Present the
sample to the MiniSipper and press the switch. The required sample volume will
be drawn into the tubing. When the system beeps remove the sample and the
required air gap will be drawn in. Once the measurement has taken place press
the switch again. The sample will be pumped out of the flowcell to waste.
When the sipper is connected a status box is displayed on the right hand side of all
the method screens that indicates the presence of the MiniSipper and its status.
SIPPER Page
* SIPPER *
SIPPER
MODE
AIR GAP
SAMPLE VOL.
SAMPLE
LOW VOL.
To change a parameter highlight the required value using the Up/Down Arrow keys
and press ENTER.
SIPPER
MODE
SIP
SIP&RUN
to
CONTINUOUS
GD Issue 1 (08/2000)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
MINISIPPER
: OFF
: SIP
: 50 cm
: 1.000 ml
: WASTE
: OFF
:
Toggle ON or OFF.
Switches the MiniSipper ON or OFF.
:
Selects from SIP / SIP&RUN / CONTINUOUS.
Sets the system to fill the flowcell.
Sets the system to fill the flowcell and automatically
perform a measurement. The current method is used
produce the result (e.g. if FIXED is current then the
sample will be measured using the FIXED METHOD as
set).
Sets the system to pump continuously to waste.
Alternate switch presses will start and stop pumping.
The instrument will not process any key presses while
the MiniSipper is pumping in continuous mode.
English
This page allows the MiniSipper to be
set up for the required analysis. The
method set on this page will be saved
with any data produced by the
software.
To reach this page press
ACCESSORIES from the MENU page
then select SIPPER and press ENTER.