Install a pressure equalization container if the leaks
cannot be eliminated (see chapter Accessories and
spare parts).
The pump stops in Automatic mode, the "Pressure
side error" LED lights up
The pump switches frequently on and off due to leaks.
1. Check the pressure side for leaks (e.g. dripping wa-
ter tap).
Install a pressure equalization container if the leaks
cannot be eliminated (see chapter Accessories and
spare parts).
2. Switch on the pump.
The pressure is too low after switching off the pump.
The device starts again immediately and switches fre-
quently on and off.
1. Increase the pressure at the pressure side.
 For garden applications, use a garden hose with
minimum length of 5 m when the diameter is ¾"
or 15 m when the diameter is ½".
 With a permanent installation, install a pressure
equalization hose or pressure equalization con-
tainer (see chapter Accessories and spare
parts).
2. Switch on the pump.
The pump stops in Manual mode, the "Pressure
side error" LED lights up
The pump runs for at least 4 minutes, although the pres-
sure side outlet (e.g. water tap) is closed. The overheat
protection switches off the device.
1. Pull the mains plug out of the socket.
Electrical connection
Mains voltage
Power frequency
Nominal power
Device performance data
Maximum flow rate
Suction height (max.)
Pressure (max.)
Delivery height (max.)
Switch-on pressure in automatic mode (max.)
Particle size (max.) of permissible feed fluids
Pump type
LED type to EN 60825-1
Application instructions
Watering (max.)
House supply (max.)
Watering + house supply with 4 persons (max.)
Dimensions and weights
Weight (without accessories)
Determined values to EN ISO 20361
Sound level L
pA
Subject to technical modifications.
12
2. Open the water dispenser connected to the pres-
sure side.
The device is depressurised.
3. Switch on the pump.
The pump capacity drops or is too low.
Dirt particles block the suction area.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
The pre-filter is soiled.
1. Pull the mains plug out of the socket.
2. Allow the pump to cool down.
3. Clean the suction area.
4. Clean the pre-filter (see chapter Cleaning the pre-
filter).
5. Flush dirt residues at the base of the filling nozzle
out through the filling hole.
6. Switch on the pump.
The suction side is leaking.
1. Check the suction side for leaks.
The maximum lifting height is exceeded or the flow rate
is not optimised.
1. Observe the maximum lifting height (see chapter

Technical data).

2. If necessary, select a different hose diameter or a
different hose length (see chapter Optimising the
flow rate).
The pressure side outlet is restricted.
1. Fully open the valve or ball tap.
The pressure side hose is kinked.
1. Eliminate the kink points in the hose.
Technical data
BP 3 Home
& Garden
V
230-240
Hz
50
W
800
l/h
3300
m
8
MPa (bar) 0,40 (4,0)
m
40
MPa (bar) 0,13 (1,3)
mm
1
Jet
Class 1
2
m
500
Persons
8
2
m
300
kg
10,3
dB(A)
61
dB(A)
76
English
BP 4 Home
BP 5 Home
& Garden
& Garden
230-240
230-240
50
50
950
1000
3800
6000
8
8
0,45 (4,5)
0,48 (4,8)
45
48
0,13 (1,3)
0,13 (1,3)
1
1
Jet
Multistage
4-stage
Class 1
Class 1
800
1000
10
12
600
800
10,6
12,5
63
61
78
77
BP 7 Home
& Garden
230-240
50
1200
6000
8
0,60 (6,0)
60
0,13 (1,3)
1
Multistage
5-stage
Class 1
1200
12
900
13,0
61
76

Quicklinks ausblenden:

Werbung

loading

Diese Anleitung auch für:

Bp 7Bp 5Bp 4