Herunterladen Diese Seite drucken

Transportation; Storage; Care And Service; Troubleshooting Guide - Kärcher SP 5 Dual Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
3. Where necessary, remove residue from
the hose and on Quick-Connect.
4. Pull the mains plug out of the socket.

Transportation

 Carry the device.
 Lift up the device by the carrying han-
dle, and carry it.
 Fasten a rope to the carrying handle,
and use the rope to lift up the device -
and carry it.
 Transport the device in a vehicle.
 Secure the device against slipping
and tipping over.

Storage

ATTENTION
Danger of frost
Incompletely emptied devices can be de-
stroyed by frost.
Completely empty the device and accesso-
ries.
Protect the device from frost.
1. Completely empty the pump.
2. Allow the pump and the hose to dry out.
3. Store the pump in a frost-protected
place.

Care and service

The device is maintenance-free.

Troubleshooting guide

Malfunctions often have simple causes that
you can remedy yourself using the follow-
ing overview. When in doubt, or in the case
of malfunctions not mentioned here, please
contact your authorised Customer Service.
The pump is running, but not delivering
Air is in the pump.
1. Pull the mains plug out of the socket and
plug it in again several times, until the
fluid is drawn in.
The suction area is clogged.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
The fluid level is too low in manual opera-
tion.
1. Immerse the pump deeper into the feed
fluid if possible, see chapter .
The pump does not start up, or stops
suddenly during operation
The power supply is disconnected.
1. Check the fuses and the electrical con-
nections.
The thermal protection switch has switched
off the pump because of overheating.
1. Pull the mains plug out of the socket.
2. Allow the pump to cool down.
3. Remove any dirt particles in the suction
area.
4. Clean the suction area.
5. Prevent the pump from running dry.
Dirt particles block the suction area.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
The pumping capacity decreases
The suction area is clogged.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
The pumping capacity is too low
The maximum delivery height is exceeded.
The hose diameter and the hose length
have been selected incorrectly.
 Observe the maximum delivery height,
see chapter Technical data.
 When necessary, select a greater hose
diameter or a shorter hose length, see
chapter Optimising the flow rate.
Quick-Connect cannot be opened or
closed
The push-fit system is dirty.
1. Remove the clip.
2. Clean the clip.
3. Install the clip.
The filter basket cannot be moved.
The filter basket is dirty.
1. Loosen the latch screws using a screw-
driver.
2. Remove the filter basket.
3. Clean the filter basket.
4. Install the filter basket.

Technical data

Electrical connection
Mains voltage
Power frequency
Nominal power
Performance data of device
Flow rate (max.)
English
V
230-240
Hz
50
W
500
l/h
9500
11

Werbung

loading