Current Consumption; Connecting Diagram; Important Notes - effeff 9334 Montageanleitung

Tuerverriegelung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical Data
Type Number
9314
6-12 V AC/DC
9314
8-16 V AC/DC
9314
24 V AC/DC
9314
8 V DC eE
9314
12 V DC eE
9314
24 V DC eE
9334
8 V DC
9334
12 V DC
9334
24 V DC
9334
42 V DC
contact load capacity of the RR (=monitoring)
contact (option)
enaging depth of the Fix counter unit into the
keeper
required clearance between striking plate an
Fix counter unit
mounting position
keeper side load
weight (without frontplate)
dimension (without frontplate)
( )
Different possibilities of electrical control
(1)
Temporary unlocking with DC or with AC
(2)
Temporary unlocking with DC or with AC /continuos unlocking with DC
(3)
Operating voltage DC
AC -> alternating tension
DC -> The use of rectified tension with 50% residual ripple is possible, but is not recommen-
ded due to the buzzing sound occurring. When using stabilized DC the buzzing sound
does not occur.

Connecting diagram

monitoring
contact
coil
(RR-option)
Illustration 18: Connecting diagram

Important notes!

1. When using fail-locked strikes (models 9314) the door cannot be opened in case of power
failure or lack of electric supply.
2. During installation and adjustment it must already be possible for the person who adjusts
the strike to unlock it electrically (see point 1).
3. During the adjustment it must be checked if the closed door is locked by the strike. If this
is not the case, readjustment at the Fix counter unit is necessary.
4. During the installation it is important that no tension occurs at the door acting on the
keeper. Any door pressure which might be caused by gaskets must be compensated by
the main lock.
Quotation and delivery according to our terms of sale and delivery
Nominal voltage
6 - 12 V AC/DC
(1)
8 - 16 V AC/DC
(1)
(1)
24 V AC/DC
8 V DC
(2)
12 V DC
(2)
(2)
24 V DC
8 V DC
(3)
(3)
12 V DC
(3)
24 V DC
42 V DC
(3)
red
The connection diagram shows the contact
position when the door is open.
green
blue

Current consumption.

Tolerance
DC
-
770 - 1450 mA
-
480 - 930 mA
± 10%
470 mA
± 10%
260 mA
200 mA
± 10%
± 10%
100 mA
230 mA
± 10%
± 10%
190 mA
± 10%
110 mA
40 mA
± 10%
max 25 V /1A
min. 2,5 mm; max. 5 mm
min. 2,5 mm; max. 5 mm
universal
not permissible
appr. 210 g
ca. 90 x 28 mm / 112 x 28 mm with RR-opt.
AC
560 - 1130 mA
340 - 700 mA
360 mA
250 mA
180 mA
90 mA
-
-
-
-