Fig. 7: Mounting tolerances, dimensions in mm

5. Electrical connection

Wiring must only be carried out with power off.
Check all lines and connections before switching
on the equipment.
Interference and distortion
All connections are protected against the effects
of interference. The location should be selected
to ensure that no capacitive or inductive in-
terferences can affect the sensor or the con-
nection lines! Suitable wiring layout and choice
of cable can minimise the effects of interference
(e.g. interference caused by SMPS, motors, cyclic
controls and contactors).
Necessary measures:
Use of screened connection cable with trunk
cable in pairs. Pairs to be allocated differential-
signal wise (D+, D-), (T+, T-), (A, /A), (B, /B)
(Recommendation: encoder/-resolver line from
Messrs. LAPP-Kabel, 5*2*0,14²+2*0,5², type-no.:
70388728).
Wiring to the screen and ground (GND) must
be secured to a good point. Ensure that the
connection of the screen and earth is made to
a large surface area with a sound connection to
minimise impedance.
The sensor should be positioned well away from
cables with interference; if necessary a protective
screen or metal housing must be provided. The
running of wiring parallel to the mains supply
should be avoided.
Contactor coils must be linked with spark sup-
pression.
Power supply:
Power consumption: <1,5W
5.1 Connection type
SSI with 12 pole coupling plug pin.
viewing side = plug-in side
MSA501, MBA501
Datum 14.12.2010
4,5VDC ... 30VDC
(with polarity protection)
Pin Signal
Signal
with LD
without LD
1
- - -
- - -
2
D+
D+
3
D-
D-
4
T-
T-
5
+UB
+UB
6
/A
- - -
7
A
- - -
8
/B
- - -
9
B
- - -
10
Config
Config
11
T+
T+
12
GND
GND
RS485 (SIKONETZ3) with 12 pole coupling plug
pin.
viewing side = plug-in side
Pin Signal
Signal
with LD
without LD
1
- - -
- - -
2
DÜA
DÜA
3
DÜB
DÜB
4
- - -
- - -
5
+UB
+UB
6
/A
- - -
7
A
- - -
8
/B
- - -
9
B
- - -
10
Config
Config
11
- - -
- - -
12
GND
GND
6. Accessory connector for connection
type
Straight mating connector (12 pole)
12 pole connector available from SIKO as acces-
sory art. no. 85277. Wire cross section is max.
0,25mm². Cable channel: 6-8mm.
Please proceed as follows (fig. 8):
1.
Slip parts 1 to 4 over outer cable.
2.
Strip cable, shorten and enlarge the screen.
Art.Nr. 85613
Description
- - -
SSI data + or DÜA in service
mode
SSI data - or DÜB in service
mode
SSI cycle input -
Power supply sensor
inverted quadrature signal
Quadrature signal
inverted quadrature signal
Quadrature signal
calibration input or swit-
ching over to service mode
SSI cycle input +
sensor earth connection
Description
- - -
Data +
Data -
- - -
Power supply sensor
inverted quadrature signal
Quadrature signal
inverted quadrature signal
Quadrature signal
calibration input or swit-
ching over to service mode
- - -
sensor earth connection
Änd. Stand 449/10
7