Insert
C2000/M2000
Note
Note
8008684/YJC8/2015-03-30
Update
Technical specifications
Safety-related parameters according to EN ISO 13849, EN 62061, IEC 61508:
C2000/M2000: General system data
Type
1)
Safety Integrity Level
1)
SIL claim limit
Category
2)
Test rate
3)
Maximum demand rate
1)
Performance Level
PFHd (mean probability of a
dangerous failure per hour)
T
(mission time)
M
The LE20 safety evaluation unit has been discontinued; alternative solutions are available
with the modular safety controller Flexi Classic.
EC declaration of conformity
The manufacturer herewith declares that the product is in conformity with the provisions of
the following EU directives (including all applicable amendments), and that the respective
standards and/or technical specifications have been applied:
 MAS-DIRECTIVE 2006/42/EC
 EMC-DIRECTIVE 2004/108/EC (valid until 19.04.2016)
 EMC-DIRECTIVE 2014/30/EU (valid from 20.04.2016)
You can obtain the complete EU declaration of conformity at www.sick.com.
1)
For detailed information on the safety design of your machine/system, please contact your local SICK
subsidiary.
2)
Internal test. The test rate may not be exceeded if an external test is performed.
3)
At least 100 internal or external tests must be performed between two demands for a safety-relevant
response of the device.
4)
The performance level does not include any specific requirements, for instance with regard to the optical
performance characteristics, etc. For more information on this refer to www.sick-safetyplus.com,
Safety Know<how.
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Type 2 (EN 61496<1)
SIL1 (IEC 61508)
SILCL1 (EN 62061)
Category 2 (EN ISO 13849<1)
13 ¹/
(EN ISO 13849)
s
8 ¹/
(EN ISO 13849)
min
PL c (EN ISO 13849<1)
Take optical performance characteristics into
4)
account!
–8
2,2× 10
20 years (EN ISO 13849)
iii