Maintenance

!
Work on electrical equipment is only to be per-
formed by persons with sufficient knowledge and
experience of electrical systems!
�.1

Cleaning

!
Do not use abrasive cleaning agents and coarse
workshop cloths!
The housing and the LCD are only to be cleaned
using a soft cloth and neutral cleaning agents.
�.2

Spare and wearing parts

Description
Charging lead with PVC insulation
Mains connecting lead
<)
Wearing part
<)
�.�

Disposal

�he BA� �1� is subject to the European
directive 2002/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of the BAT 415 prevents
environmental pollution and possible
health hazards.
Robert Bosch GmbH
Order Number
1 684 460 235
>)
1 684 460 236
Maintenance | BA� �1� | 17
6.
Technical data
Properties
Charging current
Charging lead length
*)
Charging lead cross-section
Power consumption
Weight
Characteristic charging curve
Final charge voltage at setting
> 15 °C
Voltage limit for secondary
charging at setting > 15 °C
Final charge voltage at setting
< 15 °C
Voltage limit for secondary
charging at setting < 15 °C
Back up / buffer mode
Function temperature range
Mains voltage / frequency
Mains fuse
Nominal battery voltage
Protection type (DIN 40050)
Class of protection
(DIN 40530)
Dimensions (W x H x D)
Work-related noise emission
value (Lpa)
Interference emission level
The charging leads may not be changed!
*)
en
Value, Range
Max. 15 A
2 m
4.0 mm
2
280 W
approx. 4 kg
IUIaIaI
14.0 V
14.4 V
14.4 V
14.8 V
12.0 V maximum 3 A
13.5 V maximum 15 A
0 °C to 40 °C
230 V, 50/60 Hz
H 250 T 3.15 A
12 V
IP 20
II
260 x 160 x 250 mm
70 dB(A)
DIN 40839 Interference emissi-
on level I
|
1 689 979 943
2012-10-24