1. Safety notes

1.2 Intended use

The described station is intended for primary operation of the solar substation with propylene glycol - water mix-
tures. Use of other media is not allowed.
Media temperature > 60 °C(Risk of scalding)
Setpoint and filling pressure < pickup pressure of the safety fitting
All shut-off fittings may be closed in the service case only and only if the collectors are covered as otherwise the
safety fittings lose their effect.
Caution:
Do not make any changes to electrical components, the design or the hydraulic components! Otherwise you will
impair the safe function of the system.

1.3 Initial commissioning

Before the initial commissioning, the system must be checked for any leakage as well as to make sure the hydrau-
lic linkage is correct and that the electrical connection work has been carried out with care and correctly. The sys-
tem must also be carefully flushed in accordance with DIN 4753. The initial commissioning must be carried out by
a trained specialist and a written record of it must be drawn up. In addition to this, the settings must also recorded
in writing. The technical documentation must remain with equipment..

1.4 Working on the system

The system must be disconnected from the power supply and checked to ensure it is safely isolated from the
power supply (e.g. at the separate fuse or a master switch).
Secure the system against being switched back on again.
IMPORTANT: Risk of scalding:
Media temperature > 60°C

1.5 Liability

We reserve all copyrights to this document. These installation and operating instructions must be handed over
to the customer. The skilled trades carrying out the work (e.g. fitter) must explain to the customer how the equip-
ment works and how to operate it in a way they can understand.
16

2. Technical Data

The solar station S is supplied pre-assembled as
a 1 or 2 branch type.Optionally available with solar
controller as well aspermanent venter.
For use in thermal solar collector systems with
collector areas of up to approx 12 m
(Depending on model and prevailing/existing
system parameters)
1 Safety valve integrated into the safety assembly
2 Pressure gauge
3 KFE tap with cap and hose connection nozzle
4 Solar circulation pump
5 Small distributor with 3/4"AG (outer thread)
connection for an expansion vessel
(VDI 6002 Part 1) volumetric control device
and KFE tap
6 Volumetric flow indicator
7 Shut-off ball valves 3/4" IG (internal thread) x 1" IG
(internal thread) union nut with integrated backflow
preventer (manually openable)
8 Thermometer
9 Permanent venter with quick manual venter
10 Block insulation
(One ball valve only in 1 branch solar station as well as one thermometer Item 9 omitted.)
Connections
max. permissible
temperature
max allowable pressure
Backflow preventer
Volumetric flow indicator
Thermometer
Pressure gauge
Safety valve
Dimensions
Effiziente Energietechnik
Effiziente Energietechnik
2
Solar circuit
3/4" IG (internal thread)
for expansion vessel
3/4" AG (external thread)
: +120 °C, schort periods + 140 °C (not max. permissible temp. of the pump!)
10 bar (note pick-up pressure of safety valve!)
: 1 branch: 1 x 300 mmWs
1 x 300 mm
: 2 branch: 2 x 300 mmWs
: Combination scale:
Propylenglykol 40 %
Water: 1 ... 13 l/min
A measuring capsule can be installed for recording the output or yield
(to be adjusted on site) instead of the volumetric flow indicator.
: Display range 0 ... 10 bar
: Display range 6 bar
: Achsabstand
: 100 mm
Height of insulation
: 385 mm (1 branch with control: 430 mm)
Total width
: 300 mm (1 branch: 200 mm)
Depth of insulation
: 185 mm
: 0,8 ... 10,3 l/min