Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Siko Msac506 Originalmontageanleitung

Vorschau ausblenden Andere Handbücher für MSAC506:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

MSAC506
22

Technical data

Mechanical data
Housing
Sensor/ring reading dis-
tance
Electrical data
Operating voltage
Power input
SSI clock speed input
Output circuit
Offset voltage
Interface
Cycle time
Type of connection
System data
Pole length
Resolution
System accuracy
Repeat accuracy
Circumferential speed
Fig. 4: Angled positions
8 Technical data
zinc die-cast
0.1 ... 1 mm
4.5 ... 30 V DC
<1 W
50 ... 750 kHz
1 V
±10 %
SS
2.5 V DC ±100 mV
SSI
≤30 µs
M12 connector (A coded)
5 mm
12 ... 16 bit
±0.1°
0.01°
≤32 m/s
MSAC506 · Date 08.01.2019 · Art. No. 89495 · Mod. status 284/18
Additional information
over the whole sensor line
Additional information
reverse polarity protected
Service mode (RS485)
12 poles, 1x pin
Additional information
pole number 64
~0.08° ... 0.005°
at T
= 20 °C, with run-out error
U
of 50 µm
unidirectional
absolute value ≤3 m/s
English

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis