MSAC506
Installation
4.2 Mounting the magnetic sensor
Alignment of the magnetic sensor
NOTICE
` Take care that the magnetic sensor is aligned correctly in order to
1. Fasten the Linear Encoder via two long holes on a level worktop (for
2. The position of the sensor regarding the magnetic ring is exactly
4.3 Mounting the magnetic ring
Magnetic ring MRAC506
Slide magnetic ring MRAC506 onto the shaft and then tighten grub screw
M6 to fix it to the shaft.
1. Ensure sliding fit between shaft and MRAC506.
2. Mount MRAC506 without force and without strain. Possible forces
Fig. 1: Mounting tolerances with MRAC506
MSAC506 · Date 08.01.2019 · Art. No. 89495 · Mod. status 284/18
ensure optimum sensing (see
the fastening dimensions refer to the data sheet). Optionally, you can
also use the enclosed nuts (M5).
defined. When mounting, special care shall be taken to maintain an air
gap between ring and sensor over the whole measurement distance
whether the ring or sensor is moved or not (see
aid you may use the enclosed spacing template.
should go to the metal flange. Avoid knocks on the magnetic ring.
Fig.
1).
Fig.
1
1
2
2
English
1). As a mounting
Positive rotation
direction
Admissible deviation
middle of ring/sensor
17