4 Technical Data

4 Technical Data
Device type
Meas. range
Spectral range
Measurement outlet
Accuracy
Reproducibility
Emissivity
Aiming device
Measuring distance
Measuring field diameter
Data storage classic
Data storage classic extended
Data storage ways
Power supply
Dimensions pyrometer
Weight
Housing
Test base
CE marking
CAUTION:
Never use not rechargeable batteries!
Measuring distance and measuring spot diameter
a
d
in m
b
m
in mm
a
Distance from front of housing
b
Measuring field diameter
6
KG 315 - K USB
600 . . . 1,600 °C
1.58 . . . 1.80 m
Infrared Interface from pyrometer, USB to PC
0.75 % of measured value (at 25 °C, = 1) at 550 . . . 1,600 °C
1 % of measured value (at 25 °C, = 1) at 300 . . . 550 °C
< 0.3 % of measured value (at 25 °C, = 1)
Adjustable from 0.1 . . . 1.00
Looking trough lens with integrated measuring value display
1 . . . 12 m
4.5 . . . 41.5 mm
2000 measuring values in 20 rows at 100 measuring values
About 2000 measuring values in free rows and values layout
About 1000 measuring values according to ways definition
6 x rechargeable batteries 1.2 V; 2100 mAh; NiMH
260 x 70 x 70 mm (LxWxH)
About 1.3 kg incl. 6 rechargeable batteries
Powder-coated
EN 55 011 : 1998, limit class A
According to EU regulations
1
2
3
4
5
4.5
7
9.5
12
14.5
KG 315 - K USB
300 . . . 1,200 °C
2.00 . . . 2.10 m
6
7
8
9
18
21.5
25.5
29.5
10
11
12
33.5
37.5
41.5
KG 315 - K USB

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis