Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Valve - Nibe Compact Sol Benutzer- Und Installateurhandbuch

Brauchwasserspeicher
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SERVICE
SERVICE ACTIONS

Safety valve

To check the safety valve, see section "Care and main-
tenance" on page 16.
Emptying
To drain the water heater, see section "Maintenance"
on page 16.
Resetting the temperature limiter
NOTE
Electrical installation and service must be car-
ried out under the supervision of a qualified
electrician, and in accordance with applicable
electrical safety regulations.
If the temperature limiter (FQ10) tripped, the water
heater must cool for at least one hour before it can be
reset.
Remove the thermostat knob (SF3) and the plastic
1.
cover over the connection area (QQ4).
2.
Press the button on the temperature limiter lightly.
EB1
FQ10
QQ4
Max 15 N (approx. 1,5 kg)
Reconnecting sensors
Reconnection of sensors for thermostat and temperature
L E
limiter. Check that the sensors are at the bottom of the
submerged tube.
L E
NIBE Compact Sol | GB
SF3
K
L E
K
K
L E
K
21