Please note the following basic information:
• When operating the generator at low temperatures (< 0 °C) you have to use
winter diesel fuel or you have to add a percentage of petrol to the diesel oil
according to the following table:
Ambient Temperature
–10 to 0 °C
–15 to –10 °C
–20 to –15 °C
• Always check the oil level before use (chapter "Checking the oil level" on
page 18).
• Even small overloads in the long-run will cause the generator to stop.
• Leave the generator running for a few minutes after use without any consumers
before stopping it.
• Abrupt braking, accelerating and driving round bends in the vehicle can cause
problems in the generator's pump system and lead to unwanted shutdown.
• If you are not using your generator for a longer period of time, start it up at least
every 10 days and leave it running for 15 minutes or more.
8.2
Switching the generator to standby or no function
The generator can be switched to standby or no function with the main switch
(fig. 2 1, page 3) in the connection box.
8.3
Switching the control panel on and off
This switch on the control panel (fig. 3 2, page 4) is for switching the control panel
on and off.
➤ Switch the control panel on with the on/off switch.
✓ The display shows:
The display switches off automatically after 5 minutes if the start button is not
touched within this time.
Press the start button to switch on the display again.
✓ The generator can now be started.
EN
Summer diesel
20 %
30 %
30 %
GEN OFF
.
Operating the generator
Winter diesel
20 %
15