6.5 Setting up the clamping position
1
Gas nozzle
Abb. 7
Top view of cleaning station BRS-LCi
1 Move the torch with the gas nozzle (1) vertically to the tool axis (milling cutter axis) over the cleaning
station BRS-LCi (3).
2 Move to the clamping position. Make sure that the cylindrical part of the gas nozzle (1) lies evenly
against the prism (1).
6.6 Setting up the compressed-air motor
1
Clamping device
2
Gas nozzle
Abb. 8
Setting up the compressed-air motor
1 Loosen the motor clamping in the guide block (4) by removing the screws (3).
2 Pull back the compressed-air motor (5) in its mount.
3 Place the required distance sleeve (7) on the milling cutter (6).
4 Move the torch with the gas nozzle (2) to the clamping position.
5 Keep the guide block (4) in the lower position (stroke at bottom).
6 Place the compressed-air motor (5) against the gas nozzle (2) with the distance sleeve (7) placed on
top .
7 Fasten the adjusted motor position by means of the screws (3).
8 Move the torch out of the clamping device and remove the distance sleeve (7) from the milling cutter (6).
BAL.0149.0 • 2017-05-17
1
2
Prism
1
2
7
6
5
3
Screws
4
Guide block
2
3
3
Cleaning station BRS-LCi
3
4
5
Compressed-air motor
6
Milling cutter
6 Putting into operation
7
Distance sleeve