6 Putting into operation

5.1 Cleaning station sub-assembly
1
8
7
1
S4 Inductive proximity switch (stroke on top)
2
S2 Inductive proximity switch (clamp - open)
3
Y1 5/2-way valve for milling cutter stroke (bottom - top)
4
Y3/Y4 5/3-way valve for injection unit
Abb. 3
Cleaning station sub-assembly
6 Putting into operation
Risk of injury due to unexpected start-up.
The following instructions must be adhered to for the entire duration of maintenance, servicing, mounting,
dismounting and repair work:
• Switch off the power source.
• Close the gas supply.
• Close off the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
NOTICE
• Please take note of the following instructions:
• The system may only be installed and put into operation by authorized personnel
• Make sure that the cleaning process is not impaired by the collecting tray and the bottle holder.
EN - 10
2
3
4
DANGER
 2 Safety on page EN-4
(in Germany see TRBS 1203).
5
6
5
Y2 5/2-way valve for clamping device (clamp - unscrew) and motor
(on - off)
6
S3 Inductive proximity switch (motor rotates)
7
Harting plug (optional)
8
S1 Inductive proximity switch (stroke on bottom)
BRS-LCi
BAL.0149.0 • 2017-05-17