For adjusting the spray quantity, the system must be provided with compressed air. In order to assess the
function and the spray quantity, the solenoid valve Y3 must be switched.
 Abb. 14 Connecting the pneumatic system on page EN-18
Danger of crushing
Limbs can be drawn in and crushed by moving parts (milling cutter, clamping unit).
• Do not reach between moving parts.
Damage to the eyes
Sprayed release agent may damage the eyes.
• Wear safety goggles.
• Only adjust release agent by switching the solenoid valve Y3.
1 Connect siphon hose (5) to the release agent cylinder if necessary.
2 Switch on Y4.
3 Adjust the quantity of release agent by means of the adjusting screw (4).
4 Switch off Y4.
6.9 Establishing the electrical connection
Four robot outputs 24 V DC and one robot input are required for controlling the valves.
6.9.1 Connection side HAN 16A
GND
PE
Abb. 11
Connection side HAN 16A
BAL.0149.0 • 2017-05-17
WARNING
WARNING
Voltage supply
n.c.
HAN16A
16 pins
1
n.c.
Terminal strip X1
GND
Proximity switch
Switching outputs Valve coils
24VDC
4
7
10 9
8
5
4
6 Putting into operation
6
12
13
EN - 15