3.5 Advanced settings 
 
Access the "Settings" menu by pressing 
 button as many times as needed to return to the home screen. 
Press the 
 
3.5.1 Anti‐Freeze protection 
 
The "Anti Freeze" function automatically starts the filtering pump below a certain air temperature to prevent the 
pool water from freezing. 
By default, the "Anti‐Freeze" set point temperature is set to 2°C. The setting range extends from ‐2°C to 5°C. 
INSTALL SETTINGS 
 
 
Freeze Protect 
Units 
Language 
Clear Memory 
Pump 
 
 More  
FREEZE PROTECT 
EQUIPEMENT 
 
  Filter Pump 
.   Aux1                     . 
    Aux2 
    Aux3                   
 
 The choice to activate the auxiliaries using the "Anti Freeze "mode is up to the user. 
 Filtering will remain operational as long as the air temperature has not risen above the anti‐freeze set 
 
point temperature. An "Anti‐Freeze" warning message will be displayed during this time. 
 
3.5.2 Units 
 
The units displayed by the AquaLink TRi® can be selected:  
 degrees: °C or °F 
 time : 24 hours or 12 hour (AM/PM) format.  
 
INSTALL SETTINGS 
 
 
Freeze Protect 
Units 
Language 
Clear Memory 
Pump 
 
 More  
  Select the "Unit" menu using the
  select the degrees or time menu using the
H0369400.B.EN – 2013/03
Zodiac 
14 :26 
 
Settings 
Devices 
Service Mode 
 
 
 
 More  
 and
FREEZE PROTECT
 
 
Set Temp 
Equipement 
 
 
SET UNITS 
 
 
.                °C                . 
24H 
 
 
 
 or
 
SERVICE MODE
 
 
  Auto                  .
              
.   Service                   . 
    Timeout 
 at the same time for 3 seconds. 
FREEZE PROTECT
TEMPERATURE 
 
Temp : .   2°C 
 
SET UNITS
 
 
°C 
.            24H            . 
 
 
 
 keys, then validate by pressing 
 or
 keys, then validate by pressing 
 
 
FREEZE PROTECT 
 
 
Set Temp 
Equipement 
 
 
,  