Herunterladen Inhalt Inhalt Diese Seite drucken

Installing The Remote User Interface; High Voltage Electric Connections; Wiring Diagram - Zodiac AquaLink TRi Montage- Und Gebrauchsanleitung

Schwimmbadsteuerung
Vorschau ausblenden Andere Handbücher für AquaLink TRi:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
2.2 Installing the remote user interface 
 
The user interface can be offset if access to the control box is not easy, to do this use the user interface offset kit 
(plastic cover + metal support + RJ11 cable extension, see §1.2). 
 
This  operation  must  be  carried  out  before  connecting  the  appliance  to  the  electric  power  supply 
 
(powered off). 
 
 use the user interface control box fixture support to drill 2 holes in the wall,  
 fix the support using plugs and screws (not supplied),  
 open the box cover (2 screws on the right side), 
 unscrew the user interface from the control box cover, and disconnect the installed RJ11 cable,  
 connect the supplied RJ11 extension cable, pass it through a cable gland (small model) and connect it to the user 
interface,  
 place the user interface on its support,  
 fill the user interface housing on the control box cover using the supplied plastic cover. 
 
 
If you need more than 5 metres of cable, purchase an RJ11 telephone cable of the required length from a 
 
retailer (50 meters maximum). 
 
2.3 High voltage electric connections 
 
2.3.1 Wiring diagram 
 
 
"RCD" (= Residual Current Device): ground fault protection device.  
Each  electric  power  supply  arriving  at  the  AquaLink  TRi®  control  box  must  be  protected  by  a  30mA 
 
ground fault circuit breaker and by a specific circuit breaker or protective fuse of the appropriate size. 
 
H0369400.B.EN – 2013/03
 
iAquaLink™ 
antenna‐box 
 
User 
interface
EN
 

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis