2.3.2 Power supply connection to the AquaLink TRi® control box 
 
The AquaLink TRi® control box has its own power supply. It must be permanent and protected by a 30 mA ground 
fault circuit breaker.  
Please refer to the wiring diagram §2.3.1. 
 
The use of a 30 mA Residual Current Device with a manual switch (= RCD) is mandatory to protect the 
AquaLink TRi® mains supply. It must be accessible at any time by anybody who needs to access to the 
 
unit.  
 
2.3.3 Connection to the filtering pump relay 
 
On the "FILTER PUMP" relay connect:  
  the  permanent  power  supply  to  terminals  'Line  1"  (live)  and  "Line  2"  (neutral).  This  power  supply  must  be 
protected upstream by an appropriate ground fault circuit breaker and fuse.  
 the  power  supply  cable  for  the  filtering  pump  to  terminals  "Load  1"  (live)  and  "Load  2" 
(neutral). 
 
2.3.4 Connecting auxiliary equipment 
 
Connect to relays "AUX1", "AUX2" and "AUX3":  
  the  permanent  power  supply  to  terminals  'Line  1"  (live)  and  "Line  2"  (neutral).  This 
power supply must be protected upstream by an appropriate ground fault circuit breaker 
and fuse. 
 the power supply cable for the equipment to be controlled to terminals "Load 1" (live) and "Load 2" (neutral). 
The "AUX1", "AUX2", and "AUX3" relays are free to be used to control any electric equipment compliant with the 
capacities  shown  on  the  wiring  diagram  §2.3.1  (for  example  a  booster  pump,  a  lighting  transformer,  an  extra 
pump for a water feature or a backwash, garden lighting, etc.) 
 
Do not connect multiple items of equipment to the same relay. 
 
The  relays  can  also  be  used  as  switches  for  equipment  with  an  external  electric  power  supply  that  only 
require  a  low  voltage  "on‐off"  contact  command.  In  this  case  only  use  one  side  of  the  relay:  "Line  1"  / 
 
"Load 1" or "Line2" /  "Load 2". 
 
2.4 Low voltage electric connections 
 
Low voltage connections have a reserved area on the right of the AquaLink TRi® control box. 
You can connect:  
- 1 air temperature sensor (installed at the base of the control box) 
- 1 water temperature sensor (supplied) 
- 1 "RS485" cable from the iAquaLink™ antenna‐box (supplied) 
And optionally (not supplied):  
- 1 solar temperature sensor  
- 1 heating system control cable  
- 1 "RS485" TRi® salt water chlorinator control cable  
- 1 "RS485" cable for any other iAquaLink™ compatible equipment 
 
2.4.1 Air temperature sensor connection 
 
The air temperature sensor is pre‐wired and placed at the base of the AquaLink TRi® control box.  It is imperative 
that  it  measures  outside  air  temperature,  and  it  must  be  sheltered.  If  the  control  box  is  installed  inside,  the 
temperature sensor must be installed remotely:   
- remove the sensor from the control box with its 5 metre cable,   
- fix the sensor outside, under a shelter, using the supplied fixture clip. 
 
The  air  temperature  sensor  is  especially  useful  in  managing  the  anti‐freeze  safety  device.    Zodiac® 
cannot  be  held  liable  for  damage  caused  to  the  pool  related  to  the  incorrect  location  of  the  air 
 
temperature sensor. 
 
2.4.2 Water temperature sensor connection 
 
A sensor is designed to measure water temperature and control the pool water heating system. It is supplied with 
a  5  metre  cable  (see  §1.2).  The  water  temperature  sensor  must  measure  the  temperature  before  the  heating 
system. 