1.3 Technical specifications  
 
AquaLink TRi® control box 
Size (l x h x d)   
Weight (complete appliance) 
Protection index 
Power supply 
Consumption 
Relay specifications 
Relay power equivalences 
 
2. Installation 
 
2.1 Installing the AquaLink TRi® control box 
 
 The  AquaLink  TRi®  control  box  is  ideally  located  in  a  technical  room  or  outside  in  a  sheltered  location,  and  is 
imperatively close to the pool equipment to be controlled, and sheltered from frost, and easily accessible at any 
time, 
 it must be installed  at a minimum distance from the edge of the pool in order to avoid any projections of spray 
onto  the  appliance.  This  distance  is  determined  by  the  electric  standards  applicable  locally 
(In France: 3.5 metres) 
 It must be installed on a level, ideally at 1.5 metres from the ground, 
 use the control box fixture support to drill 4 holes in the wall,  
 fix the support using the supplied plugs and screws (see §1.2),  
 open  the  control  box  cover  (2  screws  on  the  right  side)  and  drill  the  hole  in  the  side  of  the  control  box  (see 
diagram below). 
 place the control box and screw it onto the support using the supplied "M5" type screws.  
 close the control box cover. 
"M5" screws  
H0369400.B.EN – 2013/03
 
Plastic cover + metal 
support for offsetting 
the user interface 
36.5 x 30.5 x 13.5 cm 
3.5 kg 
IPX5 
220‐240 V AC / 50 Hz 
200 W / 0.9 A 
0 – 240 V AC / 25 A  
per relay 
3 HP / 1500 W 
 
RJ11 cable extension 
for offsetting the user 
interface (5 metres) 
iAquaLink™ antenna box 
Size (h x l; excluding 
the antenna) 
Power supply 
Web connection  
WiFi network 
specifications 
AquaLink TRi® control box 
 
 
 
Hardware for the 
Air temperature 
AquaLink TRi® 
sensor fixing clip 
control box 
15.0 x 10.5 cm 
RS485 
10 V DC, 180 mA 
WiFi or wired (Ethernet RJ45)
802.11b 
Open or secure, WEP or WPA 
encryption 
Wall fixture support 
and hardware 
 

Werbung