For  all  other  heating  systems,  just  serially  connect  to  the  flow  switch  (which  is  always  present  on  heating 
systems). 
 Connect a 2 x 0.75 mm² electric wire (not supplied) of the appropriate length to terminals 1 and 2 on the green 
connector of the AquaLink TRi® electronic board (see §2.3.1),  
 disconnect one of the two flow switch wires from the terminal block of the appliance to be connected (see the 
appliance instruction manual if necessary),  
 connect  the  wire  from  terminal  1  of  the  AquaLink  TRi®  in  place  of  the  wire  disconnected  from  the  heating 
system, 
 connect  the  disconnected  heating  system  wire  with  the  wire  on  terminal  2  of  the  Aqualink  TRi®  using  an 
appropriate connecting terminal, 
 set  the  heating  system  set  point  temperature  to  the  maximum.  The  AquaLink  TRi®  will  manage  the  set  point 
temperature using its own water temperature sensor. 
 
2.6 Connections to the iAquaLink
 
The  iAquaLink™  antenna‐box  is  designed  to  export  data  from  the  AquaLink  TRi®  to  internet  (via  WiFi  or  RJ45 
Ethernet cable) to be able to remotely control the pool. 
The internet connection must be stable. 
 
The iAquaLink™ antenna‐box is supplied with a wall mounting fixture kit and its quick start guide. 
 
The iAquaLink™ antenna‐box must only be installed after having made sure that the selected location 
allows  it  to  capture  the  WiFi  signal  or  be  connected  using  an  RJ45  Ethernet  cable.  Refer  to  the  quick 
 
start guide supplied with the iAquaLink™ antenna‐box to configure and synchronise with the household 
internet network. 
 
 Before fixing the antenna‐box, configure it (see quick start guide),  
 the  antenna‐box  must  be  installed  2  metres  from  the  ground  and  at  least  3  metres  from  any  electric  motor, 
appliance or metal object,  
 drill 2 holes in the wall and fix the iAquaLink™ antenna‐box using the supplied hardware kit. 
 place the iAquaLink™ "RS485" power supply cable neatly and connect it to the specific RS485 terminal block on 
the iAquaLink TRi® electronic board. The cable can be cut if it is too long. Warning: It is prohibited to extend this 
cable. 
 
H0369400.B.EN – 2013/03
 
TM
 antenna‐box 
 
A = AquaLink TRi® 
B = heating system 
C = connecting terminal block 
D = flow switch
 
 
 
 
 
1 = green 
 
2 = yellow 
 
3 = black 
 
4 = red 
 
 