Herunterladen Inhalt Inhalt Diese Seite drucken

Connection To A Heating System - Zodiac AquaLink TRi Montage- Und Gebrauchsanleitung

Schwimmbadsteuerung
Vorschau ausblenden Andere Handbücher für AquaLink TRi:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
Before installing the sensor, make sure that the filtering is stopped and that the valves  are shut. It is 
designed to be fitted to rigid PVC piping Ø50 mm, Ø63 mm or Ø1 ½''. Do not install on any other type of 
 
piping. 
 
 it  must  either  be  installed  between  the  filtering  pump  and  the  filter,  or  between  the  filter  and  any  other 
equipment,  
 drill the pipe using a Ø9 mm (Ø10 mm maximum) drill bit, then deburr the hole, 
 install the supplied O‐ring on the sensor body so that is is positioned in its groove. 
 fix the sensor using the supplied stainless steel tightening collar. Do not tighten excessively. 
 position its cable neatly and connect the end to terminals 5 and 6 of the green connector on the AquaLink TRi® 
electronic board (see wiring diagram §2.3.1). 
 
There  is  no  connection  polarity  for  the  sensor  connection.  It  can  be  shortened  if  necessary,  but  not 
 
extended. 
 
"O‐ring" seal
 
2.4.3 "Solar priority" sensor connection 
 
The AquaLink TRi® can be fitted with an extra water temperature sensor to manage a solar heating priority if the 
pool is fitted with one. 
 
This  extra  sensor  is  not  supplied  (the  required  model  is  the  same  as  the  original  water  temperature 
 
sensor), see §5.2. 
 
 The sensor must be in the immediate proximity of the solar heating system to be able to measure a coherent 
temperature. 
 to install it, proceed in the same way as for the water temperature sensor (see §2.4.2). 
 position its cable neatly and connect the end to terminals 3 and 4 of the green connector on the AquaLink TRi® 
electronic board (see wiring diagram §2.3.1).  
 
2.5 Connection to a heating system 
 
AquaLink TRi® is compatible with al types of pool heating: heat pump, heat exchanger and electric warmer. 
Thanks to its built‐in water temperature sensor, it can manage set point temperatures and thereby only start the 
heating when needed. 
 
2.5.1 Heating system equipped with a « on/off » remote control connector 
 
You  can  drive  a  heating  system  using  AquaLink  TRi®  if  it  is  fitted  with  a  specific  contact  for  a  remote  '"on‐off" 
command.  
 
Examples of compatible heating systems: 
 
 Zodiac® EdenPAC, Power First Premium,  Power Force, etc... heat pumps. 
 
 Connect a 2 x 0.75 mm² electric wire (not supplied) of the appropriate length to terminals 1 and 2 on the green 
connector of the AquaLink TRi® electronic board (see §2.3.1),  
 connect  the  appliance  contact  to  the  wire  (follow  the  connection  and  activation  procedure  for  a  remote 
"on/off" switch in the appliance installation manual), 
 set  the  heating  system  set  point  temperature  to  the  maximum.  The  AquaLink  TRi®  will  manage  the  set  point 
temperature using its own water temperature sensor. 
 
2.5.2 Heating system not equipped with a « on/off » remote control connector 
 
Examples of affected heating systems: 
 Zodiac® Power, Optipac, Powerpac, Power First, etc... heat pumps, and any other brands, 
 
 Zodiac® Red Line +, etc... electric heaters, and any other brands, 
 Zodiac® Heat Line, Uranus, etc... heat exchangers, and any other brands. 
H0369400.B.EN – 2013/03
Sensor 
 
 
 
Stainless steel 
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis