Herunterladen Inhalt Inhalt Diese Seite drucken

Environmentally Responsible Disposal - Maico MK 20 Montageanleitung

Elektrische außenklappen
Vorschau ausblenden Andere Handbücher für MK 20:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8.
Guide the cable [2] on the external wall
through the empty ducting [3] and pull it
gently until it is taut.
9.
Screw the external shutter tightly to the
wall with 4 screws. Suitable mounting
material is to be supplied by the customer.
9. Electrical connection
NOTICE
Risk of damage to unit in the event of
short-circuits. Insulate PE conductor and
individual cable cores that are not required.
● Always note the relevant specifications
for electrical installations and when fitting
equipment. In Germany, observe DIN VDE
0100 and the corresponding parts in
particular.
● The connecting duct between the external
shutter and fan terminal box must be
permanently laid.
● Only connect the external shutter parallel
to the fan.
● Do not connect the external shutter to a
controlled voltage source.
● Design according to protection class II.
1.
Switch off mains fuse, secure against
being accidentally switched back on and
position a warning sign.
2.
Perform the electrical connection in
accordance with the wiring diagrams
(Chapter 15).
10. Commissioning
1.
Check that the technical data has been
adhered to  rating plate.
2.
Ensure that the air can flow unobstructed.
3.
Switch on mains fuse, remove warning sign.
4.
Run function test. When doing so, check
for correct closing and opening functions.
11. Cleaning
If required, the unit should be cleaned with a
dry cloth. The frequency with which it should
be cleaned depends on the ambient condi-
tions and the expected impairments. Do not
use aggressive, harmful or easily flammable
cleaning agents. Swing the external shutter's
lamellae upwards in order to clean them.
The external shutter is maintenance-free.
12. Fault rectification
Fault finding and repairs should
only be carried out by trained
specialists.
Fault
Cause, measure
The external
No mains voltage.
shutter does
Check whether the mains fuse
not open or
has failed. Switch on if
close.
necessary.
13. Dismantling
Dismantling may only be undertaken
by a trained electrician.
14. Environmentally responsible
disposal
The unit and the packaging contain parts that
can be recycled, and should not end up in the
domestic waste. Dispose of the packaging
material in an environmentally-friendly way, in
compliance with the regulations valid in the
country where you are.
At the end of its service life, dispose of the
unit in an environmentally-friendly way, in
compliance with the regulations valid in the
country where you are.
6. Mounting │ UK
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis