UK │ 5. Operation

5. Operation

The external shutter is switched with a
component that is to be provided on-site.
On/off can, for example, be actuated by an
on/off switch, TH Thermostat, HY 5 Hygro-
stat, EAQ 10 Air Quality Controller, TRE...S
5-Step Transformer or an FS 4 Step Switch
 accessories.
6. Environmental conditions and
operating limits
● Ambient and airstream temperature max.
+ 40 °C.
● Storage: Store unit exclusively in a dry
location (-20 to +60 °C).
7. Technical data
For technical data  rating plate or Internet.
Rated voltage
Power frequency
Nominal power
Nominal current
Starting current
Degree of protection
Protection class
Pressure loss
Nominal sizes [N], dimensions [A]...[D]
given in [mm]
10
230 V
50 Hz
3 W, BK.. 25 W
MK..
MK.. 0.015 A,
BK.. 0.01 A
BK.. 1.8 A ‒ 1 sec.
IP 55
II (without PE
conductor)
11 Pa
N
MK 20
200
325
MK 25
250
370
MK 31
315
430
BK 20
200
325
BK 25
250
370
BK 31
315
430
8. Mounting
NOTICE
External shutter does not close properly,
if it is tensely installed. To ensure the
shutter functioning, only mount the external
shutter on a flat surface. Make sure there is
sufficient space to the wall or ceiling.
1.
Switch off mains fuse, secure against
being accidentally switched back on and
position a warning sign.
2.
Make sure the housing has a level base at
the installation location.
3.
Install a wall sleeve/ventilation channel,
with a suitable nominal diameter, in the
external wall.
4.
Install provided empty ducting [3] (for the
connecting duct) in the external wall.
Observe the position of the connec-
ting duct on the back of the housing.
For information regarding spacing
 Chapter 7.
5.
Align external shutter and mark the
positions of the 4 holes. For information
regarding spacing  Chapter 7.
6.
Drill the 4 fixing holes and insert dowels.
Suitable mounting material is to be
supplied by the customer.
7.
Press the fly screen [4] onto the studs on
the rear wall of the external shutter.
NOTICE
Shutter functioning not ensured in case
of incorrect installation. Ensure that the
cable [2] is guided tautly out of the external
shutter and that this cable does not jam the
internal slider.
A
B
C
218
275
262
320
320
380
218
275
262
320
320
380
D
83
105.5
135.5
83
105.5
135.5

Quicklinks ausblenden: