Priming time
External controls
EN 34
The priming time can be switched on
and off. It becomes active at every
pump start, in as far as it is switched on.
If the pump is currently in priming mode,
this is indicated in the operation mode
display by the text "Priming".
The speed is to be set from 50 - 100 %
and the time from 1 - 10 minutes.
In addition to ist own programmes, the
pump can also be controlled by an
external control unit.
Three setting options are available to
this purpose: "Off", "Analogue" and
"Fixed speed digital".
The signal types "Current" and "Voltage"
are available with the analogue control.
The signal range with a current control
is 0 - 20 mA or 4 - 20 mA.
The signal range with a voltage control
is 0 - 10 V or 2 - 10 V.
A minimum and a maximum speed can
be assigned in accordance with the
signal range.
If the analogue control is activated, this
is indicated in the operating mode
display by the text "Analogue".