Sound control
Via the integrated microphone the unit can perfectly reproduce the show programs (except AF12) to the
rhythm of the music (sufficient bass provided).
1
Press the MENU button so many times until Sou is indicated in the display. Confirm with the ENTER
button.
2
Use the buttons UP and DOWN to select the desired show program. SouP = Derbies and Spots, SouL =
Laser, SouF = Strobe LEDs or SouM for a combination of all devices. Confirm with the ENTER button.
3
Use the buttons UP and DOWN to adjust the number of the desired program. Confirm with ENTER.
4
Adjust the microphone sensitivity with the control SENSITIVITY. The LEDs and laser are switched off
after 5 seconds if the volume is too low or if there is no sufficient bass beat.
Individual color mix
In the color mode CoLo the white and UV strobe LEDs are switched off and the derbies and the spots light
constantly in red, green and blue. It is possible to adjust the flash frequency of the strobe LEDs and the
brightness of the spots.
1
Press the MENU so many times until CoL is indicated in the display. Confirm with the ENTER button.
The display now indicates CoLo.
2
Press the ENTER button. Now the display indicates the letter R for the color and the corresponding
brightness value.
3
Use the buttons UP and DOWN to adjust the desired brightness.
4
Confirm with the ENTER button. Now the color green can be adjusted; then blue.
5
The settings for the Derbys and spots are the last menu item. Use the buttons UP and DOWN to adjust
the flash frequency from S.01 (slow) to S.99 (fast).

Interconnecting several devices (master/slave operation)

Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
Slave units
Configure all slave units before connecting the master unit.
1
Press the MENU button so many times until SLA is indicated in the display. Confirm with the ENTER
button. The display now indicates SLAV and flashes.
2
Confirm with ENTER. The display will continue to flash until control signals are being received from the
master unit.
3
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
Master unit
Select the desired show program (automatic mode or sound-controlled mode). The interconnected light sets
will now operate in sync.